BRIDGE TDM FAQ

BRIDGE TDM FAQ

Can you give me a general overview of the TDM system?

In a Wheatstone TDM system, anything with an IP address needs to have a unique address on a common subnet. The default TDM subnet is 192.168.1.0, but you don’t have to stay with that subnet. If you do change to use another subnet, you’ll need to change the IP addressing of all your Wheatstone equipment since everything must now use an address within the new subnet. Here’s an overview of the main TDM components:

  • Tier 1— This can either be a Bridge rack with one or two CPU cards, or it may be one or two WheatNet hubs, so Tier 1 will always have either 1 or 2 IP addresses with the Tier 1 addresses set by that device’s _NET.TXT file (for Bridge and WheatNet CPU config files, the filename is XP_NET.TXT). This file is saved on the device. In very early systems a DOS configuration program was used instead of a text file. If Tier 1 has two CPUs or two hubs, then there will be a primary and a backup address. Both must be changed to the new subnet. The network settings files are accessed via FTP to the device in question and are editable using Windows Notepad. Instructions for changing these addresses are included in the Bridge and WheatNet manuals.
  • Other Tiers—Other Tiers will have CPU addresses only if they have CPU cards in them. Any of these cards can have their IP addresses changed by the FTP process using the information found in the Bridge and WheatNet manuals.
  • Control Surfaces—Control surfaces will have one or two CPUs each. They will also have device_NET.TXT files. The E-6 Surface CPU file will be named E6_NET.TXT. The procedure for editing these to change the IP address is like that used on the Bridge / WheatNet CPUs, and is covered in the Bridge and WheatNet manuals, and in the specific surface manual.
  • XPoint—The XPoint program needs to know the IP addresses of the Bridge/WheatNet CPU primary addresses, and the Surface primary addresses as well. The Bridge manual explains how to change the addresses that XPoint is looking to find CPUs and Surfaces at. Additionally, the PC running XPoint must also have an address on the common TDM system subnet.

• XY Controllers—The utility program WSNetServer is used to change XY controller IP addresses